


Enhance your R&D capabilities

Extensional Viscosity on the m-VROC II and VROC initium 1++
Extensional viscosity is a fluid's resistance to being stretched. RheoSense measures it on the m-VROC II and the VROC initium 1++ using extensional chips and small sample volumes, with the same easy workflow you use for shear viscosity.
Many real-world processes stretch fluids: a protein formulation squeezing through a needle, an ink jetting from a nozzle, a coating spraying onto a surface. Shear viscosity alone can miss how these fluids respond, and extensional viscosity can tell apart formulations that look identical in shear.
There are multiple extensional chip options to match your application. View the Extensional Chip Selection Guide (PDF)
.png?width=300&name=m-VROC%20II%20and%20CCS%20(NO%20BACKGROUND).png)
HOW EXTENSIONAL VISCOSITY IS MEASURED
Understanding Fluid Behavior — Measuring Resistance to Extensional Flow
Extensional chips contain a microfluidic contraction. As the sample flows through the contraction, the system measures the pressure upstream and downstream of it with MEMS pressure sensors and calculates the apparent extensional viscosity at a defined extension rate. The m-VROC II software (version 1.3.0.0) supports extensional viscosity measurements. Built on VROC® Technology with MEMS-fabricated chips, the platform needs only a small sample.

Extensional viscosity (m-VROC II and VROC initium 1++)
- Measured quantity: apparent extensional viscosity, from pressure measured upstream and downstream of a microfluidic contraction
- Extensional chips: EA20, EB20, EC20 and EE20
- Extension rate: set by flow rate; the software converts between flow rate (µL/min) and extension rate (1/s). Range: about 1 to 13,500 1/s, depending on chip, syringe and instrument (see the chip selection guide)
- Syringes: 100 µL and 2.5 mL
- Sample volume for an extension rate sweep: at least 80 µL (100 µL syringe) or 1.3 mL (2.5 mL syringe)
- Maximum flow rate: 1,200 µL/min (Regular pump, 100 µL syringe)
- Sample shear viscosity range: about 6 to 25,000 cP, depending on chip and syringe
- Software: m-VROC II software version 1.3.0.0 supports extensional measurements
- Sample retrieval and chip cleaning with the RheoSense Chip Cleaning Station (CCS)
- Fluids: Newtonian and non-Newtonian solutions
Extensional Viscosity FAQ
Quick answers about measuring extensional viscosity with the m-VROC II and VROC initium 1++.
Extensional viscosity is the resistance of a fluid to extensional flow, meaning flow where the fluid is stretched. Any flow involving a change in cross-sectional area is affected by it. It matters in processes such as fiber spinning, roll coating, inkjet printing, spraying and electrospinning.
Two formulations can have the same shear viscosity but behave differently when stretched. Extensional viscosity captures that difference, so it helps predict performance in nozzles, needles and spray systems.
The m-VROC II (software version 1.3.0.0) and the VROC initium 1++ support extensional viscosity measurements with extensional chips.
The sample flows through a microfluidic contraction in the chip. MEMS pressure sensors measure the pressure upstream and downstream of the contraction, and the system calculates the apparent extensional viscosity at a defined extension rate.
An extension rate sweep needs at least 80 µL of sample in the 100 µL syringe, or at least 1.3 mL in the 2.5 mL syringe. The 2.5 mL syringe is typically used for high shear or extension rate measurements.
RheoSense offers extensional chips, the EA20, EB20, EC20 and EE20, for different viscosity and extension rate ranges. See the chip selection guide for the range of each chip.
Yes. The sample retrieval feature lets you recover the sample after measurement, and the RheoSense Chip Cleaning Station (CCS) cleans the chip.
Both Newtonian and non-Newtonian fluids can be tested.
